Decoding and instructions on errors of air conditioners

According to some reports, about a third of the Russian air conditioning market is represented by the products of this company. Founded in the early 80s of the last century, the products Haier quickly gained popularity due to the high quality of technology and the use of the latest technological developments. Now Haier is one of the 100 most famous equipment manufacturers in the world, one of the first Chinese firms to officially enter the American market.

Common mistakes

Most often, the errors of Haer air conditioners are caused by improper operation and illiterate attempts to repair the devices on their own.

Having studied the error codes of haier air conditioners, it will be much easier to figure it out.

Haier air conditioner error codeBreaking
E0Violation of the condensate drain function
E1Compressor overpressure
E2Indoor unit heat exchanger covered with ice
E3Insufficient pressure in the compressor
E4 Haier air conditioner errorCompressor overheating
E5Compressor shutdown due to increased load
E6No communication between blocks
E7The indoor unit does not respond to commands from the keypad
E8Indoor unit motor overload
F0The temperature sensor in the room has disconnected
F1The temperature sensor of the heat exchanger of the indoor module is disconnected
F2The thermal sensor of the heat exchanger of the outdoor unit has disconnected
F3The outdoor thermal sensor has disconnected
F4The temperature sensor on the air supply has disconnected
FFElectricity supply interrupted

Errors on the air conditioner display

Error codes displayed on the scoreboard:

Haier air conditioner error codeNumber of diode flashesWhat does
E715No contact between outdoor and indoor units
E1 errors of air conditioners HaerThe temperature sensor in the room does not work
E2The heat exchanger sensor is broken
E4EEPROM does not function
E14Fan does not work
E9Protection sensor triggered
F12 Haier air conditioner error1Headboard short circuit
F112IPM protection enabled
F223Overvoltage is supplied to the external unit
F44There is no consistency between indoor and outdoor unit control
F116Mains voltage abnormal
F48Too hot air blown out
F2110Freezing of the temperature sensor
F612Outside air temperature sensor does not work
F25 Air Conditioner Errors Haer13Failure of the air temperature sensor at the outlet of the air conditioner
18Compressor malfunction
F1119Control board malfunction
24Compressor voltage too high or too low
25Too high voltage applied to compressor