Review and comparison of MDV air conditioners: duct, inverter, mobile and cassette systems

The brand MDV (MDV), which appeared on the market relatively recently, but has already gained good popularity, offers a wide range of climatic equipment. For a large segment of users, the most interesting are cassette and classic wall-mounted split systems. And due to the combination of price and offered characteristics, MDV channel systems enjoy a good reputation among shop and office owners.

A little about the company

President - Peter Guan.
President - Peter Guan.

Air conditioners of the MDV brand are climatic systems manufactured by the Chinese company Midea. Despite the country of origin and some fears of Russian consumers, it is worth noting that this is a really serious company that values ​​its reputation and has the quality of its products confirmed throughout the world.

To make it clear what climate systems and MDV cassette, duct and floor air conditioners are, it is worth noting: the company owns 20% of the shares of the corporation Toshiba, uses their technologies in its compressors, and solutions from MDV are installed in systems of other manufacturers as reliable and efficient. Air conditioning units MDV, in addition to parts of their own production (80% of them), use spare parts from leading brands: Danfoss, Copeland, Sanyo... Air conditioners and duct, MDV cassette systems are in demand all over the world.

Production facilities of MDV are located all over the world, including Belarus, Egypt, Brazil. It employs 150 thousand people producing high-quality spare parts and classic, cassette, duct climate systems. The research base is provided by 3 thousand scientists, and products from MDV are based on the application of 370 own technological patents for HVAC systems and parts of their engineering solutions described in the certificates.

Cassette air conditioners

Indoor unit cassette type MDV MDCA3I
Indoor unit cassette type MDV MDCA3I

Belonging to the class of semi-industrial systems, MDV cassette air conditioners provide for installation in a suspended ceiling. For this, they have specially made ceiling-type cassette units, corresponding in size to a standard panel - 60x60 centimeters. According to reviews, all models of the line are easy to install and do not create problems when designing a suspended ceiling.

However, cassette air conditioners are very attractive for ordinary consumers in terms of their characteristics. They are quite light, according to customer reviews, they are perfectly installed in a plasterboard false ceiling system, they emit very little noise and are just ideal for large rooms in modern apartments. Reviews have been expressed that directing air from the ceiling is several times more effective in maintaining the climate in the room than the flow from classic, wall-mounted split systems. The manufacturer's instructions do not limit the installation in any way, therefore, MDV cassette air conditioners are increasingly appearing in apartments.

The advantages of MDV cassette air conditioners include:

  • fully modular construction scheme, when both cassette and console modules can be connected to an external module, which is very convenient for building air conditioning in an apartment;
  • compact dimensions - only 260 mm in height and 570 mm on each side;
  • excellent performance;
  • there are no rigid installation instructions;
  • low noise level, about 40 dB in different modes.
  • The interesting functions that MDV cassette air conditioners have include:
  • separate dehumidification mode, which works without lowering the air temperature;
  • the possibility of equipping the device with an additional wired remote control for the MDV air conditioner;
  • mode of automatic control of parameters and restart in case of failures;
  • a special sleep mode, the instructions for use of which state that it not only reduces noise, but also works in a special temporal rhythm of maintaining the air temperature.

Some characteristics of MDV cassette units that will facilitate selection.

MDCA3I-09HRFN1MDCA3I-12HRFN1MDCA3I-18HRFN1
Cooling capacity, kW2,643,525,28
Heating capacity, kW2,934,15,28
Air flow, cubic meters per hour450 — 580450 — 650500 – 800
Average noise level363742

Duct air conditioners MDV

Indoor unit of channel type MDV MDTBI
Indoor unit of channel type MDV MDTBI

A duct air conditioner (multi-zone system) is designed to provide the desired climate inside a large office with several rooms. Mounted above the false ceiling, the duct unit is hidden from view, and the air is distributed through ducts that are routed to the desired points. Devices of this class have high performance.

When it comes to products from MDV, customer reviews indicate that ducted air conditioners can maintain the climate inside a small house. They are quiet, the instructions for use ensure excellent working conditions inside the house. Also, the presence of both cooling and heating modes make MDV ducted air conditioners an excellent solution for private residences.

The undoubted advantages of ducted air conditioners include low noise, as well as small dimensions (only 210 mm in height), which improves the conditions of use and placement inside the apartment. In addition, the operating instructions of the device declare enough freedom for the users - the air conditioner does not require special installation or maintenance.

The list of features possessed by MDV duct air conditioners is as follows:

  • there is no manual for specific installation conditions;
  • when turned on, the system smoothly raises the speed of the turbines depending on the temperature change of the coolers, which leads to a smooth outlet of cool air without causing any unpleasant sensations for people in the room;
  • low noise level;
  • automatic restart and control;
  • separate special mode of operation at night.

As evidenced by reviews, the reliability of MDV equipment fully complies with the characteristics declared by the manufacturer, the air conditioners are quiet, efficient, there are instructions for use and installation.

Mobile and wall-mounted split systems MDV

Despite the fact that the company on the market is the most common industrial air conditioners MDV, they also produce household inverter models: mobile and wall systems. The differences between the models are quite diverse, therefore it would be more correct to compare their technical characteristics and additional functionality in the table.

Mobile air conditioners MDV

ModelMPN1I-09ERN1MPGi-09ERN1MPN1I-12ERN1
Cooling power, W260026003500
Heating power, W147010001760
Power consumption during cooling, W101010101350
Power consumption when heating, W147010001760
Noise level, dB505448

Wall mounted air conditioners

ModelMDSR-07HRN1 / MDOR-07HN1MDSR-09HRN1 / MDOR-09HN1MDSF-12HRN1 / MDOF-12HN1MDSF-18HRN1 / MDOF-18HN1
Air flow, m³ / min5,8389,6713,33
Cooling power, W2100260033705274
Heating power, W2100260035205570
Power consumption during cooling, W64082010501640
Power consumption when heating, W6097709751540
Noise level, dB32343033

Instructions for control panel and MDV air conditioners

Instructions for wired remote control

Remote control instructions

Error codes for air conditioners MDV

As you know, there are no eternal things and a situation may arise when the MDV air conditioner simply does not turn on. Before grieving over costly repairs, you should call a wizard or independently determine the nature of the malfunction using the error codes given in the electrical diagram or instructions for the device.

Most of the faults and errors are identified by the internal control system of the device, and the corresponding codes, separate for the indoor and outdoor unit, are indicated by LEDs on the panels and control boards. The LED can be on, blinking, and the specific combination indicates the nature of the error. These can be prerequisites for cleaning, adjusting or even repairing the device when it does not react at all to control programs.

Signal lamps 4. These are Run, Timer, Defrost, Alarm. The Run light, when blinking, most often indicates a failure of various sensors. The number and frequency with which the indicator flashes determine the error codes. As an example, a group of errors can be given: E2 - E4 - "Run blinking" - malfunction of the room air temperature sensor, evaporator control sensor, errors in determining the outlet flow temperature. Also, when the Run lamp is blinking, this may mean a failure of the internal memory or an E7 error when reading data from it.

Timer LED displays communication error codes. For example, when it blinks at a frequency of 5 Hz, it means communication errors between the outdoor and indoor unit. The batteries may even just run out.

Sometimes block error codes directly indicate a malfunction of the associated equipment. For example, when the Alarm indicator flashes slowly at the indoor unit, it means that the air conditioner does not turn on due to a malfunction of the outdoor unit. Conversely, a similar LED on the outside is an error code indicating problems with the indoor unit. You may even have to change some parts.

Detailed error codes for each model are given in the user manual. It also contains information on how to fix some faults and problems yourself. A complete list of codes can be found in the reference materials for Midea air conditioners - most of the LED signal combinations are the same as MDV products.

Error codes for MDV household air conditioners

Error codes multi-split systems MDV

MDV semi-industrial error codes

User reviews

Because the company's products are represented by several types of lines, reviews are often quite contradictory. Some people have a household air conditioner, while industrial installations are head and shoulders above their competitors and vice versa. Let's look at the main advantages and disadvantages of the brand as a whole, based on customer reviews.

Pros:

  • quiet work;
  • fast cooling;
  • justifies its price;
  • quite stylish design.

Minuses:

  • loud external unit;
  • there are models with a noisy compressor;
  • loud mode switching.
myhome.decorexpro.com/en/