How to calculate the flow rate of water through a pipe by pressure and diameter

When laying water mains, the most difficult thing is to calculate the throughput of pipe sections. Correct calculations will ensure that the water flow rate is not too large and its pressure does not decrease.

The importance of correct calculations

Calculation of water consumption allows you to choose the right material and pipe diameter

When designing a cottage with two or more bathrooms or a small hotel, it is necessary to take into account how much water the pipes of the selected section can supply. After all, if the pressure in the pipeline drops with a large consumption, this will lead to the fact that it will be impossible to take a shower or a bath normally. If a problem arises in a fire, you may even lose your home. Therefore, the calculation of the passability of highways is carried out even before the start of construction.

For small business owners, it is also important to know the throughput rates. Indeed, in the absence of metering devices, utilities, as a rule, present an invoice for water consumption to organizations according to the volume passed by the pipe. Knowing the data on your water supply will allow you to control water consumption and not pay extra.

What determines the permeability of the pipe

Water consumption will depend on the configuration of the water supply system, as well as the type of pipes from which the network is mounted

The permeability of pipe sections is a metric value that characterizes the volume of liquid passed through the pipeline for a certain time interval. This indicator depends on the material used in the manufacture of pipes.

Plastic pipelines maintain almost the same permeability throughout the entire operating period. Plastic, in comparison with metal, does not rust, thanks to this, the lines do not become clogged for a long time.

For metal models, the throughput decreases year after year. Due to the fact that pipes rust, the inner surface gradually flakes off and becomes rough. Because of this, much more plaque forms on the walls. In particular, hot water pipes clog up quickly.

In addition to the material of manufacture, the permeability also depends on other characteristics:

  • The length of the plumbing. The greater the length, the lower the flow rate due to the influence of the friction force, and the pressure also decreases accordingly.
  • Pipe diameter. The walls of narrow lines create more resistance. The smaller the cross-section, the worse the ratio of the flow rate to the value of the internal area in the section of a fixed length will be. In wider pipelines, water moves faster.
  • The presence of bends, fittings, adapters, taps. Any fittings slow down the movement of water flows.

When determining the indicator of throughput, it is necessary to take into account all these factors in combination. In order not to get confused in numbers, it is worth using proven formulas and tables.

Calculation methods

The coefficient of friction is influenced by the presence of locking elements and their number

To determine the permeability of the water supply system, you can use three calculation methods:

  • The physical way. To find out the indicators, formulas are used. To calculate, knowledge of several parameters is required, in particular, the size of the section of the pipe section and at what speed the water moves in the pipeline.
  • Tabular method.It is the simplest one, because by picking up indicators in the table, you can immediately find out the necessary data.

    Water supply calculation program
  • Computer programming. Such "software" is easy to find and download on the Internet. It is specially designed for finding the permeability of pipes of any system. To find out the required parameter, you need to enter the starting data into the program: material, length, quality of the coolant.

The last method, although the most accurate, is not suitable for calculating ordinary household communications. It is quite complex, and for its application you will need to know a variety of indicators. To calculate a simple network for a private house, you should resort to using an online calculator. Although not as accurate, it is free and does not need to be installed on a computer. You can get more accurate information by comparing the data calculated by the program with the table.

How to calculate bandwidth

The tabular method is the simplest. Several tables of counting have been developed: you can choose the one that is suitable depending on the known parameters.

Calculation based on pipe section

In SNiP 2.04.01-85, it is proposed to find out the amount of water consumption by the pipe circumference.

External section of the line (mm)Approximate amount of liquid
Liters per minuteCubic meters per hour
20150,9
25301,8
32503
40804,8
501207,2
6319011,4

In accordance with the SNiP standards, the daily water consumption by one person is no more than 60 liters. This data is for a house without running water. If a water supply network is installed, the volume increases to 200 liters.

Calculation based on the temperature of the coolant

As the temperature rises, the permeability of the pipe decreases - the water expands and thereby creates additional friction.

You can calculate the required data using a special table:

Pipe section (mm)Bandwidth
By heat (hl / h)By heat carrier (t / h)
WaterSteamWaterSteam
150,0110,0050,1820,009
250,0390,0180,6500,033
380,110,051,820,091
500,240,114,000,20
750,720,3312,00,60
1001,510,6925,01,25
1252,701,2445,02,25
1504,362,0072,83,64
2009,234,241547,70
25016,67,6027613,8
30026,612,244422,2
35040,318,567233,6
40056,526,094047,0
45068,336,0131065,5
50010347,4173086,5
60016776,52780139
7002501154160208
8003541625900295
90063329110500525
1000102047017100855

For the connection of the plumbing system, this information is not extremely important, but for heating circuits it is considered the main indicator.

Searching data depending on pressure

The water flow pressure of the common line is taken into account when selecting pipes

When selecting pipes for the installation of any communication network, it is necessary to take into account the flow pressure in the common line. If a high pressure head is provided, pipes with a larger cross-section must be installed than when moving by gravity. If, when selecting pipe sections, these parameters are not taken into account, and a large water flow is passed through small networks, they will make noise, vibrate and quickly become unusable.

To find the largest calculated water flow, a table of pipe throughput is used depending on the diameter and different indicators of water pressure:

ConsumptionBandwidth
Pipe section15 mm20 mm25 mm32 mm40 mm50 mm65 mm80 mm100 mm
Pa / mMbar / mLess than 0.15 m / s0.15 m / s0.3 m / s
90,00,90017340374516272488471696121494030240
92,50,92517640775616522524478897561515630672
95,00,95017641476716782560486099001537231104
97,50,975180421778169925964932100441555231500
100,01000,0184425788172426325004101521576831932
120,01200,0202472871189728985508111961735235100
140,01400,0220511943205931435976121321879238160
160,01600,02345471015221033736408129962016040680
180,01800,02525831080235435896804138242142043200
200,02000,02666191151248837807200145802264445720
220,02200,02816521202261739967560153362376047880
240,02400,02886801256274041767920160562487650400
260,02600,03067131310285543568244167402592052200
280,02800,03177421364297043568568173382692854360
300,03000,3317671415307846808892180002790056160

The average pressure in most of the risers varies from 1.5 to 2.5 atmospheres. The dependence on the number of floors is regulated by dividing the water supply network into several branches. Water injection by means of pumps also affects the change in flow rate.

Also, when calculating the water flow through the pipe according to the table of pipe diameter and pressure values, not only the number of taps is taken into account, but also the number of water heaters, baths and other consumers.

Hydraulic calculation according to Shevelev

For the most accurate identification of the indicators of the entire water supply network, special reference materials are used. They define the running characteristics for pipes made of different materials.

An example of a good model for calculations is Shevelev's table. This is a voluminous reference book. You don't have to go to the library to use it. All the data you need can be found on the World Wide Web. In addition, there are electronic programs based on Shevelev tables. It is enough to enter the required parameters to get the finished result.

Applying formulas

The application of different formulas depends on the known data. The simplest of them: q = π × d² / 4 × V.In the formula: q shows the water flow rate in liters, d is the cross-section of the pipe in cm, V is the speed indicator of the hydraulic flow advance in m / s.

The speed parameters can be taken from the table:

Water supply typeSpeed ​​(m / s)
City water supply0,60–1,50
Main pipeline1,50–3,00
Central heating network2,00–3,00
Pressure system0,75–1,50

When connecting additional pumping devices, it is necessary to take into account the coefficient of the created pressure. It is listed in the user manual.

Knowing what characteristics the pipes have is necessary for the competent connection of plumbing fixtures. With the correct selection of data, there will be no reason to worry that when you open the tap in the bathroom, the water in the kitchen will stop flowing or its pressure will decrease.